Power station for a CPAP: nights per charge, with the humidifier
Sized for one 8-hour night with the heated humidifier on, which is the draw that decides everything. Start with enough capacity for the humidifier, and check whether your machine supports a compatible DC cable to reduce conversion losses. Start with Jackery Explorer 1000 v2 for enough capacity without carrying a much larger battery.
Try Prime free before you use the Amazon buttons below: 30 days free, then $14.99 a month, cancel any time. A paid link, like the Amazon buttons.
Best for CPAP3.8/5 overall
Score from the maker's figures and 4 independent reviews
Why it’s here Holds 1,070 Wh against the 627 Wh needed for a night of CPAP and a 3,000 W surge for the 124 W start-up. 23.8 lb, one of the lightest options with enough power.
Why it’s here Holds 1,024 Wh against the 627 Wh needed for a night of CPAP and a 3,600 W surge for the 124 W start-up. $529 ($0.52 per Wh), a lower-cost way to cover a night of CPAP.
Why it’s here Holds 1,024 Wh against the 627 Wh needed for a night of CPAP and a 4,400 W surge for the 124 W start-up. 28.7 lb, check that this carry weight suits you.
46 of 56 current units hold enough over 1 day. The watt-hours include inverter losses and 20% spare; the start-up figure is what the largest motor draws for an instant. See the arithmetic.
What decides a CPAP night
One CPAP night, humidifier on: 53 W × 8 hours = 424 Wh
Jackery Explorer 1000 v2: 1,070 Wh at the end marker. Required with losses and headroom: 599 Wh. Unfilled space is remaining capacity. Assumes 85% AC efficiency; check output and startup power separately.
One CPAP night, humidifier off: 45 W × 8 hours = 360 Wh
Device 360 Wh · Losses 64 Wh · 20% headroom 85 Wh
Jackery Explorer 1000 v2: 1,070 Wh at the end marker. Required with losses and headroom: 509 Wh. Unfilled space is remaining capacity. Assumes 85% AC efficiency; check output and startup power separately.
The machine and its heating settings matter. The examples use 45 W without a heated humidifier and 53 W with one. They are planning examples, not a before-and-after measurement of the same machine. With this page's starting appliances, a night needs 627 Wh. A compact battery does not automatically cover the night, even without a humidifier. Check your own machine's draw and the hours you need. If you use a DC converter cable, it must be compatible with both the CPAP and the station's port. The custom load calculator separates DC energy from AC energy and leaves cable compatibility for you to check.
Nights per charge, humidifier off, for the picks: Jackery Explorer 1000 v2 about 2.5 nights (2.1 with it on); EcoFlow DELTA 3 Classic about 2.4 nights (2.1 with it on); DJI Power 1000 about 2.4 nights (2.1 with it on); capacity × 0.85 ÷ device watts ÷ 8 hours.
The load, device by device
Over 1 day. Device watt-hours ÷ 0.85 for the inverter, × 1.2 for headroom, gives the 627 Wh above; the start-up peak adds the largest single surge among these devices to the running total.
Devices in this job
Device
Watts
Hours a day
Wh a day
Start-up W
CPAP machine (with heated humidifier) (rated)
53
8
424
104
Smartphone charger (USB-C) (rated)
20
1
20
–
Every unit that clears it
Listed lightest first, because this unit gets carried.
46 units
46 units that hold 627 Wh and clear 124 W at start-up
Tick appliances from the device table, or add your own appliance using its label or a plug-in watt meter. Keep a preset only if it matches the equipment you plan to run.
Any picks earlier on this page use the starting appliances. Your changes update the calculator and its table below.
For a well pump, furnace or house inlet, check the connection before choosing by watts. The home-backup guide explains what an electrician needs to check.
Home
h/dayrated 90 W
h/dayrated 180 W
h/dayavg 41 W · start-up 1,300 W
h/dayrated 10 W
h/dayrated 1,500 W
h/dayrated 1,116 W · start-up 2,900 W
h/dayrated 89 W
Medical
h/dayrated 45 W
h/dayrated 53 W · start-up 104 W
h/dayrated 120 W
Camp and outdoors
h/dayrated 6 W
Work and tools
h/dayrated 1,800 W · start-up 2,300 W
h/dayrated 40 W
h/dayrated 20 W
h/dayavg 88 W
h/dayrated 24 W
Add your own appliances
Your entries stay in this tab. They are not saved in a link or sent with calculator events.
Use running watts while the appliance is on. For a cycling fridge or pump, enter the hours connected and the percentage of that time it runs. If your watts are already a daily average, leave duty at 100%. Startup watts must include the full startup draw, not just the extra watts.
Rated capacity you need
627Wh
AC running peak
73W
AC start-up peak
124W
Devices draw 444 Wh over1 days. 444 ÷ 0.85 × 1.2 gives the rated Wh to buy.
The loss allowance is an estimate. Headroom adds 20% to the energy requirement. All selected appliances can run together; copies in the same custom row can start together.
DC rows use this separate estimate. The default keeps the same loss allowance as AC; change it only if you know the efficiency of your cable and converter. Port voltage, current and shared limits still need checking.
46 of 56 tracked units fit
Units that fit the requirement above, sorted by price per Wh
They are arithmetic: capacity × 0.85 ÷ device watts. Real hours depend on temperature, battery age and the exact device; the constants are stated so you can adjust them, and every device draw in the calculator can be changed.
What if nothing fits?
Shorten the hours, drop a device, or move it to DC. The calculator recomputes as you change it, and the checkbox under its table shows every unit with the reason it fails, which usually points at one device.
Why is the pick not the biggest unit?
Because the job is fixed, and once a unit clears it, more capacity is weight and money for nothing. Choose the weight, recharge time and expansion options you will actually use.