Glossary
Power station terms, in plain words
Every column in the spec table uses the manufacturers' own units. These are the ones that decide a purchase.
Last materially reviewed
Terms
Read the first four and you can read any spec sheet: watt-hours say how long, watts say how much at once, surge says whether a motor will start, and chemistry says how many years it lasts.
- Wh (watt-hour)
- the energy the battery stores. A 1,000 Wh unit can supply 100 W for about 10 hours before losses. This is the capacity figure on every spec sheet and the one the sizing calculator solves for.
- kWh (kilowatt-hour)
- 1,000 Wh. Brands use it for large units; this site converts everything to Wh so rows compare.
- W (watt), continuous
- the power the inverter can deliver steadily through the AC outlets. Every device you run at once adds up against this number.
- Surge W (peak W)
- the short burst the inverter can deliver for a fraction of a second to a few seconds, which is what a compressor or a motor draws when it starts. A fridge rated 100 W running can pull 800 to 1,200 W at start-up.
- Boost mode (X-Boost, Power Lifting and similar)
- a manufacturer mode that runs a resistive load (heater, kettle) above the continuous rating by lowering the voltage. It is not the continuous rating and this site never records it as one.
- LiFePO4 (LFP, lithium iron phosphate)
- the cell chemistry now used by most current units. Typically rated 3,000 to 4,000 or more cycles, heavier per Wh, and more tolerant of heat than NMC.
- NMC (NCM, ternary lithium)
- the lighter chemistry used in earlier units and some current light ones. Typically rated 500 to 1,000 cycles.
- Cycle life
- the number of full charge and discharge cycles after which the battery still holds a stated share of its original capacity, usually 80%. '3,000 cycles to 80%' means after 3,000 full cycles the unit still holds at least 80% of its rated Wh. The share matters as much as the count.
- Depth of discharge (DoD)
- how much of the battery a cycle uses. Manufacturers' cycle claims assume their own DoD, which is why cycle counts across brands are only roughly comparable.
- Inverter efficiency
- the share of stored energy that reaches an AC device; the rest is lost as heat in the inverter. Manuals typically state 85% to 90%. The calculator divides by 0.85.
- MPPT (maximum power point tracking)
- the charge controller that draws the most a solar panel can give at any moment. Every current unit has one; the number that matters is the maximum solar input in W, which caps how fast any panel can recharge the unit.
- Solar input (max)
- the most solar power the unit will accept, in W. A 400 W panel on a unit with a 200 W input charges at 200 W at best.
- AC input (max)
- the most the unit draws from a wall outlet while charging, in W. Together with capacity it sets the wall recharge time.
- Recharge time
- the manufacturer's stated time from empty to full (or to 80%, where that is what they publish) from the wall or from solar at the maximum input under their conditions.
- UPS / EPS switchover
- when the unit sits between the wall and a device, the time it takes to switch to battery when the wall fails, in milliseconds. Under about 20 ms most computers and CPAP machines do not notice; some brands publish 10 ms, some 20 ms, some 30 ms, and some publish nothing.
- Pass-through charging
- using the unit's outlets while it is charging from the wall or solar.
- Expandable
- the unit accepts add-on batteries. The maximum expanded capacity is the total Wh with every supported add-on attached.
- USB-C PD (Power Delivery)
- the USB-C standard that lets a port supply up to 100 W (PD 3.0) or 140 W and beyond (PD 3.1) to a laptop. The table records the highest single USB-C output.
- Solar generator
- marketing name for a power station sold in a bundle with one or more solar panels. Nothing is generated; the station stores energy and the panel replaces it. The station's specs are what matter.
- Price per Wh
- the current official price divided by rated capacity. The neutral way to compare cost across sizes; this site's price-sorted tables use it.
Every term above is a column or a note in the spec database. Theexplainer puts them in order, and the sizing calculator uses the ones that decide fit.