As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure.
Solar generator or gas generator?
A solar generator, a power station with its panels, keeps going for as long as each day's sun puts back what you used, with no fuel or fumes; a gas generator, for as long as you keep filling it, but only outdoors. For an outage kit of a fridge, router, phones and lights, 32 of the 118 stations we have solar setups for keep going on a good day of sun, the lowest-cost kit at about $2,097 for station and panels; a Honda EU2200i burns about 2.8 gallons a day doing the same at a quarter load, the lightest Honda gives.
From each maker's published figures and our own arithmetic; we have not tested these setups or the generator ourselves.
Your station, on sun or on gas
Example: the EcoFlow DELTA Pro with an outage kit. Pick your own station and load.
On its battery alone, the EcoFlow DELTA Pro holds about 1.6 days of it, with our 20% margin.
On sun, 5 × BLUETTI PV200 puts a day's use back in about 2.8 hours of full sun, so a good day keeps it going, day after day.
A Honda EU2200i inverter generator runs 8.1 hours on its 0.95-gallon tank at a quarter of its rating, the lightest load Honda publishes, so plan on about 3 tankfuls (2.8 gallons) a day for this, run outdoors and refilled with the engine cool.
Charged from a generator like it, the DELTA Pro's AC input takes up to 1,800 W, and EcoFlow gives a full charge from empty at that rate in about 2.7 hours, which burns at most about 0.8 gallons in the EU2200i; then the generator can stop for a quiet night.
Every panel on the DELTA Pro, with prices and the cold-morning check
The lowest-cost solar generators that keep an outage kit going
Of the 118 stations with a solar setup, 33 hold a day of the outage kit on their battery, and 32 of those have a maker panel setup that puts the day's 1,940 Wh back in 5 hours of full sun or less at a 70% panel yield. These are the 10 lowest-cost pairs of station and panels, before cables.
| Station | Days on its battery | Panels | Full sun to put a day back | Station and panels |
|---|---|---|---|---|
| Dabbsson DBS2300 Plus | 1 | 2 × EcoFlow 400W | 3.5 h | $2,097 |
| Dabbsson 3000L | 1.3 | 2 × EcoFlow 400W | 3.5 h | $2,197 |
| Pecron F3000LFP | 1.3 | 6 × Anker SOLIX PS100 Bifacial | 4.6 h | $2,278.94 |
| Aferiy P310 | 1.7 | 2 × EcoFlow 400W | 3.5 h | $2,397 |
| BLUETTI Elite 300 | 1.3 | 2 × EcoFlow 400W | 3.5 h | $2,397 |
| OUPES Mega 3 | 1.3 | 2 × EcoFlow 400W | 3.5 h | $2,497 |
| Allpowers R3500 | 1.4 | 6 × Anker SOLIX PS100 Bifacial | 4.6 h | $2,578.94 |
| Anker SOLIX F3000 | 1.3 | 3 × Anker SOLIX PS200 Bifacial | 4.6 h | $2,599.96 |
| Allpowers R4000 | 1.5 | 3 × Jackery SolarSaga 200W | 4.6 h | $2,636 |
| BLUETTI Apex 300 | 1.2 | 2 × EcoFlow 400W | 3.5 h | $2,697 |
Where the gas generator wins
- Heavy loads. A 1,500 W space heater draws about 1,760 Wh from a battery for each hour it runs, so even the largest station we list (12,288 Wh) runs it for about 7 hours. The EU2200i runs 3.2 hours a tank at its full 1,800 W, and keeps going for as long as you refill it. Central air or an electric range needs a larger generator, or a wired home battery. A well pump is a 240 V motor with a hard start: 9 of the 129 stations we list have a 240 V outlet of their own and the surge to start Franklin's 1/2 HP 2-wire pump, through a transfer switch an electrician fits, and the battery sets how many days of water you get (the well pump check).
- A long run of dark days. When cloud or snow covers the panels for days, a solar generator lives on its battery alone, and a generator keeps going for as long as you can buy and store fuel.
- Watts for the money. For the same running watts, a generator costs less to buy than a battery that holds many hours of them; the battery's case rests on fuel, noise and fumes.
Where the solar generator wins
- Indoors and at night. A power station makes no exhaust, so it can sit beside the fridge or the bed; only the panels go outside, in daylight. A generator must stay outdoors, more than 20 feet from the house (CDC guidance).
- No fuel to buy or store. After a storm, fuel can be hard to find just when you need it, and stored gas goes stale. The sun's part costs nothing once the panels are bought.
- Quiet. Honda rates the EU2200i, one of the quieter generators, at 48 dB(A) at a quarter load and 57 dB(A) at full load; a power station makes only its cooling fan's noise.
- Little to keep up between outages. Honda asks EU2200i owners to change the oil after the first 20 hours, to add stabilizer to fresh gasoline when it will sit a month or two, and to drain the carburetor when it runs less than once a month. A power station asks for a check and a charge every few months in storage, by its maker's manual (storing a power station).
- It is already on. 93 of the 129 stations we list switch to battery within 30 ms when the grid fails, by their makers' figures, so a fridge plugged through one stays cold. Whether a CPAP rides through a gap that short depends on the machine, so ask its maker before you rely on it overnight (UPS switchover times).
Cloudy days, winter, and using both
The days on the battery are what carry you through cloud. A day of thick overcast gives a small part of a sunny day's watt-hours, and a December day gives a panel tilted for winter about 2.5 hours of full sun in Chicago (every city's winter sun), so size the battery for the run of dull days you expect, then the panels for the good days between. Panels also face a cold-morning voltage limit; each setup page checks it at -10 °C (14 °F).
Many owners keep both: the station runs the house quietly through the night, and on a dark day the generator runs for a few hours to refill it through the station's AC input, then stops. That burns far less fuel than running a generator round the clock for a fridge and a router. Never connect either to house wiring without the transfer equipment a qualified electrician installs; the battery-and-generator guide covers the safety rules.
Questions buyers ask
Is a solar generator better than a gas generator?
For a fridge, a router, phones, lights or a CPAP, yes when its panels can put a day's use back in a good day's sun: 32 of the 118 stations we have setups for do that for the outage kit on this page. For central air, an electric range or a long run of dark days, a gas generator does what no portable battery can. A well pump needs a station with a 240 V outlet and the surge to start it: 9 of the 129 we list have both, and the well pump check gives the days of water each holds.
How long can a solar generator run?
As long as its battery lasts, plus what the sun puts back each day. The EcoFlow DELTA Pro holds the outage kit for about 1.6 days on its battery alone, and 5 × BLUETTI PV200 put a day's use back in about 2.8 hours of full sun, so on sunny days it keeps going indefinitely.
How much fuel does a generator use in a day?
It depends on the generator and the load: the spec sheet gives the hours per tank. The Honda EU2200i runs 8.1 hours on 0.95 gallons at a quarter load and 3.2 hours at full load, so round the clock at a quarter load it needs about 3 tankfuls (2.8 gallons) a day.
Can I run a solar generator indoors?
The power station, yes: it makes no exhaust. Keep it inside the temperature range its manual gives and the panels outside in the sun. A gas generator never runs indoors, in a garage or under an open window.
Where the figures come from
- Honda EU2200i specifications: "AC Output 120V 2200W max. (18.3A), 1800W rated (15A)" · "Fuel Tank Capacity .95 gal" · "Run Time per Tankful 3.2hr @ rated load 8.1 hrs @ 1/4 load" · "Noise Level 57 dB(A) @ rated load 48 dB(A) @ 1/4 load" · "Dry Weight 47.4 lb."
- Honda EU2200i owner's manual and Honda's fuel advice: "Maintenance Before each use Check engine oil level. Check air filters. First 20 hours Change engine oil." · "1 to 2 months Fill with fresh gasoline and add gasoline stabilizer" · "If you do not plan to operate the generator frequently (less than once a month), drain the carburetor following the directions shown in the owner's manual."
- Loads: the calculator's ready-made devices, with an 85% inverter allowance; a station holds a load when its capacity covers it with a 20% margin and its outlets cover the running and startup watts.
- Solar: each station's maker input limits and each panel's maker figures, at a 70% panel yield; the setup pages give every source.