What extension cord does a power station or generator need?

Divide the load's watts by 120 for its amps, then take a cord rated for those amps at the length you need. Up to 50 ft, a 16-gauge cord carries 13 A and a 14-gauge cord 15 A. At 100 ft, 16 gauge drops to 10 A and 14 gauge to 13 A, and you need 12 gauge for 15 A. No cord with ordinary plugs is rated over 15 A. The sum is the same for a gas generator and a power station; on a station, the heat a thin cord gives off comes out of the battery.

Which cord carries your load?

Example: a corded 7-1/4-inch circular saw, rated 1,800 W, on 100 ft of cord for an hour of cutting. Type your own load and length over it.

1,800 W at 120 V draws 15 A. Over 100 ft, the thinnest cord rated for it is 12 gauge (12/3, rated 15 A up to 100 ft). It drops 4.8 V (4%) and turns 72 W into heat.

Over 1 hour that is 72 Wh of the station's charge spent warming the cord, 4% of what the load itself uses; a 10-gauge cord would spend 45 Wh.

Each gauge with 15 A over 100 ft of cord, thinnest first
CordRated forVolts lostHeat in the cordCarries it?
16 gauge (16/3) 10 A up to 100 ft 12.1 V (10%) 181 W no, too thin
14 gauge (14/3) 13 A up to 100 ft 7.6 V (6.3%) 113 W no, too thin
12 gauge (12/3) 15 A up to 100 ft 4.8 V (4%) 72 W yes
10 gauge (10/3) 15 A up to 100 ft 3 V (2.5%) 45 W yes

Ratings for three-wire cords, from Coleman Cable's table on Wikipedia's extension cord page; they stop at 100 ft. Volts lost and heat from copper's resistance at 68 °F in the National Bureau of Standards' Copper Wire Tables (Table 6), counted out and back along the cord at 120 V; a warm cord loses a little more. Where your cord's own tag gives a lower rating, the tag wins.

A short cord saves battery

Every cord turns a little of the current into heat, and the share of power it wastes is the same as the share of volts it drops: a cord that drops 4% of the 120 V also wastes 4% of what the load draws. From a gas generator that costs fuel. From a power station it comes out of the battery, so the hours our runtime pages give shrink by about that share.

Generator cords run long because the generator has to stay outdoors: the CDC says "Only use generators outside, more than 20 feet away from your home, doors, and windows". A power station makes no exhaust, so it can sit beside the load on a short cord, or the cord can be thicker than the rating needs. On the example, 100 ft of 12-gauge cord wastes 72 W at full load; the station beside the saw, with no extension cord, wastes none.

Power stations with a 30 A outlet, and the plug each takes

A station's ordinary 120 V outlets take an ordinary three-prong plug, and the table above covers them. Larger stations add a 30 A or 50 A outlet for an RV, a generator inlet or a 240 V load. That outlet needs a cord with the matching plug, rated for 30 A or 50 A on its tag; none of the household cords above fits it. 30 of the stations we track list one on the unit itself, by their makers' own pages and manuals:

Stations whose maker lists a 30 A or 50 A outlet on the unit, largest AC output first
StationThe maker's outletThe cord's plugAC output
EcoFlow DELTA Pro Ultra X twist-lock (L14-30R), 120/240 V, 30 A; 14-50R, 120/240 V, 50 A L14-30P, a four-prong twist-lock; 14-50P, the 50 A four-prong plug 12,000 W
EcoFlow DELTA Pro Ultra 120/240 V, 30 A outlet, shape not named the matching plug: check the socket's shape 7,200 W
Jackery Explorer 5000 Plus twist-lock (L14-30R), 120/240 V, 30 A; 14-50R, 120/240 V, 30 A L14-30P, a four-prong twist-lock; 14-50P, the 50 A four-prong plug 7,200 W
Pecron F5000LFP twist-lock (L14-30R); RV outlet (TT-30R) L14-30P, a four-prong twist-lock; TT-30P, the 30 A RV plug 7,200 W
Anker SOLIX F3800 14-50R, 120/240 V; twist-lock (L14-30R), 120/240 V 14-50P, the 50 A four-prong plug; L14-30P, a four-prong twist-lock 6,000 W
Anker SOLIX F3800 Plus 14-50R, 120/240 V; twist-lock (L14-30R), 120/240 V 14-50P, the 50 A four-prong plug; L14-30P, a four-prong twist-lock 6,000 W
OUPES Guardian 6000 V2 twist-lock (L14-30R), 120/240 V; 14-50R L14-30P, a four-prong twist-lock; 14-50P, the 50 A four-prong plug 6,000 W
Pecron E3800LFP RV outlet (TT-30R) TT-30P, the 30 A RV plug 4,200 W
EcoFlow DELTA Pro 3 RV outlet (TT-30R); twist-lock (L14-30R), 120/240 V TT-30P, the 30 A RV plug; L14-30P, a four-prong twist-lock 4,000 W
Jackery HomePower 3600 Pro Max 14-50R, 240 V, 16.7 A, 4,000 W 14-50P, the 50 A four-prong plug 4,000 W
BLUETTI Apex 300 RV outlet (TT-30R); 14-50R TT-30P, the 30 A RV plug; 14-50P, the 50 A four-prong plug 3,840 W
Zendure SuperBase V4600 RV outlet (TT-30R) TT-30P, the 30 A RV plug 3,800 W
Allpowers R4000 30 A outlet, shape not named the matching plug: check the socket's shape 3,600 W
Anker SOLIX F3000 RV outlet (TT-30R) TT-30P, the 30 A RV plug 3,600 W
EcoFlow DELTA 3 Ultra 30 A outlet, shape not named the matching plug: check the socket's shape 3,600 W
EcoFlow DELTA 3 Ultra Plus 120 V, 30 A outlet, shape not named the matching plug: check the socket's shape 3,600 W
Goal Zero Yeti PRO 4000 RV outlet (TT-30R), 30 A TT-30P, the 30 A RV plug 3,600 W
Jackery HomePower 3000 120 V, 30 A outlet, shape not named the matching plug: check the socket's shape 3,600 W
Jackery HomePower 3600 Plus RV outlet (TT-30R), 120 V, 30 A TT-30P, the 30 A RV plug 3,600 W
OUPES Mega 3 RV outlet (TT-30R) TT-30P, the 30 A RV plug 3,600 W
Pecron E3600LFP RV outlet (TT-30R) TT-30P, the 30 A RV plug 3,600 W
Aferiy P300 RV outlet (TT-30R) TT-30P, the 30 A RV plug 3,000 W
Mango Power E 30 A outlet, shape not named the matching plug: check the socket's shape 3,000 W
OUPES Mega 2 RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,500 W
OUPES Mega 2 Pro RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,500 W
Anker SOLIX C2000 Gen 2 RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,400 W
Anker SOLIX F2600 RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,400 W
BLUETTI AC200L RV outlet (TT-30R), 120 V, 30 A TT-30P, the 30 A RV plug 2,400 W
BLUETTI Elite 300 RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,400 W
Dabbsson DBS2100 Pro RV outlet (TT-30R) TT-30P, the 30 A RV plug 2,400 W

Each outlet links to the maker's page or manual it is read from. "Shape not named" means the maker gives the outlet's amps but not its NEMA shape; look at the socket before buying a cord. The station's AC output is shared by all its outlets, so a 30 A outlet on a 2,400 W station gives at most 2,400 W, not the 3,600 W that 30 A at 120 V could carry.

Can you power the house through an extension cord?

No. The CPSC's warning is plain: "NEVER try to power the house wiring by plugging the generator into a wall outlet". A cord with a plug on both ends feeds the house wiring backwards through an outlet, with no switch to keep that power off the utility's lines, where it can electrocute a line worker. OSHA puts it the same way: "Never attach a generator directly to the electrical system of a structure (home, office, trailer, etc.) unless a qualified electrician has properly installed the generator with a transfer switch". A cord can run appliances straight from the station or generator; house circuits need a transfer switch or the station maker's own home panel. Home backup names the stations that have one, and the power station or generator guide compares the two for an outage.

Outdoors, in rain and on a reel

Questions buyers ask

What gauge extension cord do I need for a generator?

Divide the load's watts by 120 for the amps, then take a cord rated for them at your length. By Coleman Cable's ratings: up to 50 ft, a 16/3 cord carries 13 A and a 14/3 cord 15 A; up to 100 ft, 16/3 carries 10 A, 14/3 13 A, and 12/3 or 10/3 15 A. A power station's 120 V outlets need the same cord.

Is a 12-gauge cord enough for a 1,800 W tool?

Yes, up to 100 ft: 1,800 W is 15 A, and a 12/3 cord is rated 15 A at that length. At 50 ft or less, a 14/3 cord carries it too. Past 100 ft the ratings we use stop; a thicker cord drops fewer volts.

Can I plug my house into a power station with an extension cord?

No. The CPSC says: "NEVER try to power the house wiring by plugging the generator into a wall outlet". A cord with a plug on both ends feeds the house wiring backwards through an outlet, with no switch to keep that power off the utility's lines. House circuits need a transfer switch fitted by an electrician, or the maker's own home panel for a station that has one; home backup has the stations and their connections.

Does a long extension cord waste battery?

Yes: the cord turns some of the current into heat, and the share it wastes equals the share of volts it drops. 15 A through 100 ft of 14/3 cord would waste about 113 W, which is more than its rating allows; through 12/3 it is 72 W. Keep the station close to the load: it makes no exhaust, so unlike a gas generator it need not sit 20 feet from the house.

Which power stations have a 30 amp outlet?

30 of the stations we track list a 30 A or 50 A outlet on the unit, among them 18 with an RV outlet (TT-30R) and 7 with a 120/240 V twist-lock (L14-30R). The table on this page names each one and the plug it takes.

Your shortlist

Compare power stations

Runtime is rated capacity × 0.85 ÷ watts. Check startup draw and connections separately. Prices are the maker's, with the day they were checked.