powerstations.reviews

As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure.

Anker SOLIX C1000 Gen 2 vs EcoFlow DELTA 3

Two 1,024 Wh units on the same shelf at different prices: Anker's C1000 Gen 2 against EcoFlow's DELTA 3. The C1000 Gen 2 is the cheaper energy, 8% less per watt-hour at the makers' prices, gives 200 W more continuous output and is 2.7 lb lighter. The DELTA 3 takes an extra battery: buy it for that, and the C1000 Gen 2 for the money once Anker SOLIX has it in stock.

Capacity
1,024 Wh
1,024 Wh
AC output
2,000 W
1,800 W
Surge
3,000 W
3,600 W
Solar input
600 W
500 W
Weight
24.9 lb
27.6 lb

Anker SOLIX

Anker SOLIX C1000 Gen 2

$529.99 $699.99 at Anker SOLIX

pre-order only when checked Nov 16, 2026 · $0.52 per Wh

$469.99 to $549.99 in our checks since Oct 7

Top and front, to scale: 15.12 × 8.19 × 9.61 in. Ruler: 12 in.
Capacity
1,024 Wh
AC output
2,000 W
Surge
3,000 W
Solar input
600 W
Weight
24.9 lb

Buy it if you want the most stored energy per dollar ($0.52 against $0.57 per Wh).

Full specs

EcoFlow

EcoFlow DELTA 3

$579 $699 at EcoFlow

checked Nov 17, 2026 · $0.57 per Wh

$564 to $629 in our checks since Oct 7

Top and front, to scale: 15.7 × 8 × 11.2 in. Ruler: 12 in.
Capacity
1,024 Wh
AC output
1,800 W
Surge
3,600 W
Solar input
500 W
Weight
27.6 lb

Buy it if you may want to add a battery later.

Full specs

Amazon offers a free 30-day Prime trial, with free delivery on eligible items. Try Prime free (a paid link, like the Amazon buttons).

Figure by figure

Compare the differences that matter for your devices; Anker SOLIX C1000 Gen 2 leads on 8, EcoFlow DELTA 3 on 2, and the rest are equal or not comparable.

Every figure both makers publish
FigureC1000 Gen 2DELTA 3
Capacity 1,024 Wh 1,024 Wh
Output (surge) 2,000 W (3,000 surge) 1,800 W (3,600 surge)
Weight 24.9 lb 27.6 lb
Price $529.99 $699.99 at Anker SOLIX, pre-order only when checked Nov 16, 2026 $579 $699 at EcoFlow, checked Nov 17, 2026
Price per Wh $0.52 $0.57
Chemistry – LiFePO4
Rated cycles 4,000 to 80% 4,000 to 80%
Max solar input 600 W 500 W
Max AC input 1,600 W 1,500 W
Wall recharge 49 min to full 56 min to full
Expandable no yes, to 5,000 Wh
UPS switchover 10 ms 10 ms
AC outlets 5 6
USB-C ports 3 2
Warranty 5 years 5 years
Dimensions 15.12 x 8.19 x 9.61 in 15.7 x 8.0 x 11.2 in

Cycle counts are highlighted only when both makers rate them to the same remaining capacity. A full recharge is not ranked against a charge to 80%. Missing figures never count as an advantage. These are manufacturer ratings; matching endpoints do not prove identical test conditions.

Rated cycles: C1000 Gen 2, 4,000 to 80%; DELTA 3, 4,000 to 80%.

How the comparison is worked out
Where each figure comes from
FigureC1000 Gen 2DELTA 3Meaning
Capacity C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Output (surge) C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Weight C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Price C1000 Gen 2 price source · checked Nov 16, 2026DELTA 3 price source · checked Nov 17, 2026 As the maker states it; a dash where not published
Price per Wh C1000 Gen 2 price source · checked Nov 16, 2026DELTA 3 price source · checked Nov 17, 2026 Price ÷ rated Wh; calculated, not measured
Chemistry C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Rated cycles C1000 Gen 2 spec sheetDELTA 3 spec sheet Stated cycles and remaining-capacity percentage; conditions may differ
Max solar input C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Max AC input C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Wall recharge C1000 Gen 2 spec sheetDELTA 3 spec sheet Keep the full or 80% charge endpoint
Expandable C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
UPS switchover C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
AC outlets C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
USB-C ports C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Warranty C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published
Dimensions C1000 Gen 2 spec sheetDELTA 3 spec sheet As the maker states it; a dash where not published

Estimated AC energy = rated Wh × 0.85. Runtime = estimated AC energy ÷ load W, with no reserve. Capacity and weight differences use the displayed figures; price per Wh uses each model's own price and the day it was checked. The device draws are in the watt-hour calculator.

Will it run your gear?

Check whether each unit has enough battery and output for the devices you want to run.

Can it run this?
UseNeedsC1000 Gen 2DELTA 3
a day of home backup (a full-size refrigerator, a router, phones and lights for a day) 2,323 Wh, 161 W running, 1,351 W startup no: too little capacity no: too little capacity
a night of CPAP (a CPAP with its humidifier for one 8-hour night) 599 Wh, 53 W running, 104 W startup yes yes
two nights of camping (camp lights, phones, a laptop and a fan for two nights) 2,066 Wh, 157 W running, 157 W startup no: too little capacity no: too little capacity
a day in an RV (a day of RV lights, TV, phones and a laptop) 648 Wh, 156 W running, 156 W startup yes yes
a working day in a van (a working day of laptop, Starlink, lights and a fan) 1,674 Wh, 189 W running, 189 W startup no: too little capacity no: too little capacity
a laptop and two phones (a laptop for six hours and two phone charges) 396 Wh, 60 W running, 60 W startup yes yes

Runtime by device

Hours = capacity × 0.85 ÷ device watts, with the draws from the device table; "Start" says whether the output and surge ratings cover the startup figure we use for each device (the refrigerator, 1,300 W startup allowance, from a larger 27 cu ft Whirlpool's tech sheet), so a "yes" there means likely, not certain, to start yours.

Hours on a full charge
DeviceDraw WC1000 Gen 2 hStartDELTA 3 hStart
CPAP machine (with heated humidifier) 53 16.4 yes 16.4 yes
Refrigerator (full-size, ENERGY STAR, ~18 cu ft top freezer) (average draw) 41 21.1 yes 21.1 yes
Laptop (MacBook Air, charging) 40 21.8 yes 21.8 yes
Wi-Fi router 24 36.3 yes 36.3 yes
Starlink Mini (router built in) 33 26.8 yes 26.8 yes
TV, 50-inch LED / Crystal UHD 89 9.8 yes 9.8 yes
Space heater, 1500 W 1,500 0.6 yes 0.6 yes

Buy the C1000 Gen 2 if…

  • you want the most stored energy per dollar ($0.52 against $0.57 per Wh)
  • the $49.01 difference matters more than the specs
  • you carry it more than you run it (24.9 lb against 27.6 lb)
  • you need more continuous output (2,000 W continuous and 3,000 W surge, against 1,800 W and 3,600 W)
  • you need a higher solar input ceiling (600 W against 500 W); actual recharge depends on the panels
Top and front, to scale: 15.12 × 8.19 × 9.61 in. Ruler: 12 in.

Buy the DELTA 3 if…

  • you may want to add a battery later
Top and front, to scale: 15.7 × 8 × 11.2 in. Ruler: 12 in.

More models from both brands: Anker SOLIX and EcoFlow. Every model we list: all 129 in one table. Your own devices: the watt-hour calculator.

Questions buyers ask

Which is better for power outages, the C1000 Gen 2 or the DELTA 3?

Anker SOLIX C1000 Gen 2 states a 10 ms switchover, so it can sit between the wall and a fridge or router and take over when the power cuts, once the device is in an outlet the manual gives the backup to and any AC timeout is off (for a CPAP or a computer, check that device rides through the switch); EcoFlow DELTA 3 states 10 ms. Capacity: 1,024 Wh each. Check your appliance's startup watts against the surge figures in the table.

Which is cheaper per watt-hour?

C1000 Gen 2 at $0.52 per Wh against $0.57. This compares purchase price with rated capacity, not lifetime delivered energy.

Can either run a window air conditioner?

Only if the air conditioner's running watts stay under the AC output (2,000 W on the C1000 Gen 2, 1,800 W on the DELTA 3) and its start fits the surge figures in the table: read both on the air conditioner's label or in its manual, and test it before you rely on it. For the hours, multiply the rated Wh by 0.85 for inverter losses and divide by the running watts. A 5,000 BTU window unit such as GE's AHEC05AC draws 455 W while the compressor runs, and we allow 1,800 W for its start: both units' surge figures cover that start. On a full charge it would run about 1.9 hours on the C1000 Gen 2 and about 1.9 hours on the DELTA 3, with the compressor running without a break; a thermostat that switches it off in a cool room stretches that.

Your shortlist

Compare power stations

Runtime is rated capacity × 0.85 ÷ watts. Check startup draw and connections separately. Prices are the maker's, with the day they were checked.